Why design matters

Good boats aren't wired by guesswork.

Modern yachts carry more power, more electronics and more stored energy than ever. Putting real design work in before the first wire is pulled is what keeps that system safe, reliable and easy to own.

Lithium changes the math

Lithium iron phosphate banks have far lower internal resistance than the lead-acid and AGM batteries they replace. That's great for charging and heavy loads — but it also means a short circuit can deliver tens of thousands of amps almost instantly.

A fuse or breaker that was fine on an old AGM bank may not be rated to safely interrupt that much current. A short-circuit analysis confirms every protective device can actually do its job.

AGM bank

~6 kA

typical fault current

Lithium bank

20 kA+

typical fault current

Example figures for a similar-size house bank; actual values depend on the battery and cabling.

10 A100 A1 kA10 kA100 kA1000 s100 s10 s1 s0.1 s0.01 sAGM fault ≈ 6 kALithium fault ≈ 20 kA
100 A fuse100 A breakerCable damage curveIllustrative only. The protection curves must sit to the left of, and below, the cable's damage curve at every fault level the battery can deliver.

Size the cable to the protection

Every fuse and breaker has a time-current curve: how long it takes to trip at a given current. Every cable has a damage curve: how long it can carry that current before the insulation fails.

Proper design picks the cable and the protective device together, so the device always opens before the wire overheats — across overloads and full short circuits. Breakers and fuses behave very differently, and choosing the wrong one can leave a cable unprotected right where it matters most.

Generators like to work

Diesel generators run best at roughly 60–80% of their rated load. In that range they burn hot enough to clear carbon and fully burn fuel.

An oversized generator that spends its life lightly loaded never gets hot enough — unburned fuel and soot build up in the exhaust ("wet stacking"), gumming up the engine and shortening its life. A proper load analysis sizes the generator for how the boat is actually used.

Generator load

0%Sweet spot 60–80%100%
  • Under 40% — carbon buildup and wet stacking
  • 60–80% — clean, efficient, long life
  • Over 90% — little headroom for motor starts

The payoff

Design once. Benefit for the life of the boat.

Quicker installation

Technicians work from a clear plan with wire runs, sizes and labels already decided — less guesswork, fewer hours on the clock.

Easier troubleshooting

Accurate schematics and labeled circuits mean a fault can be traced in minutes, years later, by anyone.

Smoother integration

Nav-com, AV, lithium, inverters and generators are planned to work together instead of being bolted on one at a time.

Start a project